Main Menu
|
|
Home Members options Search |
|
|
|
|
User Info
|
|
 Welcome Anonymous
|
|
|
|
|
The Simpsons
|
|
|
|
|
|
|
|
Downloads › Linear Accelerators
Main | Add Download |
New Downloads |
Random
Commissioning, calibration, and QA of linacs, IMRT, IGRT, treatment planning systems, etc.
| Annual report |
v1.0 |
Rating:  |
Popularity:  |
Published: Mon Jun 12, 2006 9:27 pm |
|
| Annual QA report for a Varian. |
| |
|
| Daily Warm-Up Check for Linacs |
|
Rating:  |
Popularity:  |
Published: Fri Apr 17, 2009 12:56 pm |
|
| An MS EXCEL based daily log for monitoring the output of linear accelerators using a 5 point monitor chamber. |
| |
|
| Data Comparison of 10 Varian LINACs in North America |
|
Rating:  |
Popularity:  |
Published: Sat Jul 31, 2010 5:55 am |
|
| Off axis ratio from Beam Profiles can be matched by fine adjustments of PDD. Data from 10 different Varian LINACs were compared. Output factors and Wedge factors were within 1% if measured the same way. Data was also compared to Varian's Golden Beam Data. |
| |
|
| Fast Real Time Calibration of Varian Linacs |
|
Rating:  |
Popularity:  |
Published: Sat Jul 26, 2008 1:54 pm |
|
Fast Real Time Calibration of Varian Linacs from 2008 AAPM poster session SU-GG-T-208.
No voltmeter required. +/-0.2% accuracy in a few minutes.
Please see warnings.
Varian's method requires a voltmeter. This method does not: |
| |
|
| High energy linac shielding report |
v1.0 |
Rating:  |
Popularity:  |
Published: Fri Oct 19, 2007 3:35 pm |
|
| This is a shielding report for a new high energy (6/23 MV) installation, with calculations based on NCRP 151. |
| |
|
| Modified Winston-Lutz Test for IGRT Setups |
v1.0 |
Rating:  |
Popularity:  |
Published: Fri Jul 09, 2010 2:45 pm |
|
| Brief document describing the clinical implementation of a modified Winston-Lutz test. This test measures IGRT system end-to-end positioning accuracy with a precision of ~0.1 mm. It can be performed in less than 5 minutes. |
| |
|
| Monthly calibration form |
Editor's Pick
v1.01 |
Rating:  |
Popularity:  |
Updated: Thu Jun 15, 2006 10:20 pm |
|
| Simple Excel sheet for monthly calibration, PDD, and linearity tests for SSD calibrations. Ppol is not included. |
| |
|
| MU Calculation Spreadsheet for Linac |
|
Rating:  |
Popularity:  |
Published: Mon Feb 25, 2008 2:29 pm |
|
| Just a sample spreadsheet to compute or verify your TPS MU computation for 6 MV and 15 MV photons. |
| |
|
| TG-142 Physics QA Checklist |
|
Rating:  |
Popularity:  |
Published: Tue May 25, 2010 7:31 pm |
|
| This EXCEL spreadsheet copies all tables in Klein et al's TG-142 paper of September 2009. |
| |
|
| TG51 Calibration |
v3.2.2 |
Rating:  |
Popularity:  |
Published: Wed May 26, 2010 5:14 pm |
|
| TG-51 Calibration Workbook |
| |
|
| Varian EDW Data |
|
Rating:  |
Popularity:  |
Published: Sat Jan 06, 2007 12:03 pm |
|
| This is a spreadsheet compilation of data sent to me. The data is presented as I recieved it, except for some formatting fixes for printing. I claim no credit for clever work nor accept responsibility for accuracy. We should all be grateful for the kindes |
| |
|
| Varian MLC test shapes |
v1.0 |
Rating:  |
Popularity:  |
Published: Mon Jun 12, 2006 9:31 pm |
|
| Varian MLC square fields and closed fields for 52 and 120 leaf MLCs, useful for commissioning and light/radiation field measurements. |
| |
|
Page: 1
|