Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Category: Linear Accelerators
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: alfredotomas1980
New Today: 0
New Yesterday: 0
Overall: 952

People Online:
Members: 0
Visitors: 22
Total: 22
Who Is Where:
 Visitors:
01: Downloads
02: External downloads
03: Downloads
04: External downloads
05: Downloads
06: Downloads
07: Downloads
08: Downloads
09: Downloads
10: External downloads
11: External downloads
12: Downloads
13: Downloads
14: Downloads
15: Downloads
16: Downloads
17: Downloads
18: Downloads
19: Downloads
20: Downloads
21: Home
22: External downloads

Staff Online:

No staff members are online!
Downloads › Linear Accelerators

Main | Search | Add Download | New Downloads | Random

Sort: Title Ascending Descending   Published Ascending Descending   Updated Ascending Descending   Rating Ascending Descending  


Commissioning, calibration, and QA of linacs, IMRT, IGRT, treatment planning systems, etc.

 Sample iComCAT files for NCS report 24
No screenshot
Rating: Not rated Popularity: 3/5: Average Published: Fri Oct 02, 2015 11:33 am
Download Now
A sample of a few iComCAT files used as part of VMAT commissioning for an Elekta VersaHD following NCS report 24.
Submitted by: rtphysicist Homepage 0 reviews

 Survey of SRS Cone Factors
No screenshot
Rating: Below average Popularity: 3/5: Average Published: Tue Jan 06, 2015 2:06 pm
Download Now
Survey of SRS Cone Factors by Rick Peters
Submitted by: scottdube Homepage 1 review

 Matlab script for generating Elekta Agility iCom files
Rating: Rubbish Popularity: 3/5: Average Published: Fri Jul 26, 2013 11:08 am
Download Now
Contains function write_rectangular_efs() will generates an iCom file for an arbitrary rectangular field. Function call_write_efs() illustrates its usage. Scripts are for Agility model only, but could be modified for other machines.
Submitted by: cejones Homepage 1 review

 EGS_Window in Matlab
Rating: Good Popularity: 2/5: Slightly below average Published: Fri Aug 10, 2012 12:05 pm
Download Now
EGS_WINDOWS is a matlab version of the EGS_WINDOW code (that was developed and distributed for Linux systems).

USAGE: EGS_WINDOWS('*.egsgeom','*.egsgph')
EXAMPLE: For one of the BEAMnrc examples EX10MeVe:
EGS_WINDOWS('EX10MeVe.egsgeom','EX10MeVe.e
Version 1
Submitted by: bakhtiari Homepage 1 review

 Patient Gantry Collision Check
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Mon Jul 23, 2012 12:57 pm
Download Now
A macro enabled excel spreadsheet to check for patient gantry collision when planning SBRTs or RapidArcs. Gantry and couch data was measured on a Varian Trilogy.
Version 1.0
Submitted by: Jigar Homepage 0 reviews

 A Practical Guide to TG-142 QA
Rating: Very good Popularity: 5/5: Very popular Published: Tue Feb 14, 2012 11:39 pm
Download Now
This is a Word document and XLS file designed to assist clinical physicists with implementing AAPM TG-142 recommendations for linear accelerator QA. It provides examples of tests that can be performed to fulfill TG-142’s recommendations.
Version 1.0
Editor's Pick Submitted by: jrjones Homepage 1 review

 Varian DynaLog File Anonymizer
Rating: Not rated Popularity: 2/5: Slightly below average Updated: Wed Aug 10, 2011 6:59 am
Download Now
Program to automatically anonymize Varian DynaLog files.
Version 1.01
Submitted by: nathanchildress Homepage 0 reviews

 Pinnacle_Script_for_Naming_All_Beams
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Fri Oct 08, 2010 10:12 am
Download Now
This Pinnacle Script is to be used with NameBeam.Script (Pinnacle_Script_for_Naming_Beams), and will change the name of all the radiation beams in one trial to reflect the angle of incidence relative to the patient.
Submitted by: Choldsw Homepage 0 reviews

 Pinnacle_Script_for_Naming_Beams
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Fri Oct 08, 2010 10:11 am
Download Now
This Pinnacle Script will rename a radiation beam based on the angle of incidence relative to the patient. The .txt extension on the file can be changed to .Script.
Submitted by: Choldsw Homepage 0 reviews

 IMRT QA scripts for creating phantom plan (Pinnacle 8.0m)
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Mon Sep 20, 2010 11:08 am
Download Now
Pinnacle (ver 8.0m) scripts for expediting IMRT QA
Submitted by: vjeevan Homepage 1 review

 Data Comparison of 10 Varian LINACs in North America
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Sat Jul 31, 2010 4:55 am
Download Now
Off axis ratio from Beam Profiles can be matched by fine adjustments of PDD. Data from 10 different Varian LINACs were compared. Output factors and Wedge factors were within 1% if measured the same way. Data was also compared to Varian's Golden Beam Data.
Submitted by: kchu2 Homepage 1 review

 Modified Winston-Lutz Test for IGRT Setups
Rating: Not rated Popularity: 3/5: Average Updated: Wed Apr 13, 2011 6:32 pm
Download Now
Brief document describing the clinical implementation of a modified Winston-Lutz test. This test measures IGRT system end-to-end positioning accuracy with a precision of ~0.1 mm. It can be performed in less than 5 minutes.
Version 1.1
Submitted by: nathanchildress Homepage 0 reviews

 Varian High Energy Linac Replacement Part QA Guidelines
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Mon Jun 14, 2010 9:10 pm
Download Now
List of Varian recommended QA checks for high energy linacs to perform after replacement of various common parts.
Submitted by: zulloj Homepage 0 reviews

 TG51 Calibration
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Wed May 26, 2010 4:14 pm
Download Now
TG-51 Calibration Workbook
Version 3.2.2
Submitted by: bkurko Homepage 0 reviews

 Varian Low Energy Linac Replacement Part QA Guidelines
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Tue May 25, 2010 9:37 pm
Download Now
Table of Varian recommended checks to perform after replacement of linac components.
Editor's Pick Submitted by: zulloj Homepage 0 reviews

 TG-142 Physics QA Checklist
No screenshot
Rating: Not rated Popularity: 3/5: Average Published: Tue May 25, 2010 6:31 pm
Download Now
This EXCEL spreadsheet copies all tables in Klein et al's TG-142 paper of September 2009.
Submitted by: rbenson Homepage 0 reviews

 Physics check date calculator
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Tue May 25, 2010 6:30 pm
Download Now
Used for calculating the dates for weekly physics checks.
Submitted by: rbenson Homepage 0 reviews

 Daily Warm-Up Check for Linacs
No screenshot
Rating: Below average Popularity: 1/5: Not popular Published: Fri Apr 17, 2009 11:56 am
Download Now
An MS EXCEL based daily log for monitoring the output of linear accelerators using a 5 point monitor chamber.
Submitted by: rbenson Homepage 1 review

 Radiation warning signs (Word files)
Rating: Not rated Popularity: 2/5: Slightly below average Published: Thu Aug 14, 2008 6:28 pm
Download Now
Radiation warning signs in editable Microsoft Word documents.
Version 1.0
Submitted by: nathanchildress Homepage 0 reviews

 Fast Real Time Calibration of Varian Linacs
No screenshot
Rating: Very good Popularity: 3/5: Average Published: Sat Jul 26, 2008 12:54 pm
Download Now
Fast Real Time Calibration of Varian Linacs from 2008 AAPM poster session SU-GG-T-208.
No voltmeter required. +/-0.2% accuracy in a few minutes.
Please see warnings.
Varian's method requires a voltmeter. This method does not:
Submitted by: kchu2 Homepage 1 review

Page: 1, 2  Next

Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.
Interactive software released under GNU GPL, Code Credits, Privacy Policy