Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Category: Treatment Planning
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: alfredotomas1980
New Today: 0
New Yesterday: 0
Overall: 952

People Online:
Members: 0
Visitors: 15
Total: 15
Who Is Where:
 Visitors:
01: Downloads
02: Downloads
03: Downloads
04: Downloads
05: Downloads
06: Downloads
07: Downloads
08: FAQs
09: Downloads
10: External downloads
11: Home
12: External downloads
13: Downloads
14: Downloads
15: Downloads

Staff Online:

No staff members are online!
Downloads › Treatment Planning

Main | Search | Add Download | New Downloads | Random

Sort: Title Ascending Descending   Published Ascending Descending   Updated Ascending Descending   Rating Ascending Descending  


External beam treatment planning systems and MU check tools.

 A Simple Low Cost Deep Inhalation Breath Hold System
No screenshot
Rating: Below average Popularity: 4/5: Popular Published: Sun Sep 07, 2014 11:06 am
Download Now
We describe how to implement a simple and low cost method for DIBH using equipment found in most radiation oncology clinics or easily purchased.
Submitted by: kchu2 Homepage 1 review

 Adac ROI Translator
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Wed Jun 14, 2006 6:16 pm
Download Now
This program will translate a region of interest file (ROI) in adac. It will also flip the data if needed. The user has to ftp the file from the unix box into a pc and make sure it is a dos mode text file. Then you can run the program on the file.
Submitted by: dcheek Homepage 0 reviews

 Automated Plan DVH Comparison for Eclipse (v13 Compatible!)
Rating: Not rated Popularity: 4/5: Popular Updated: Thu Oct 19, 2017 7:28 pm
Download Now
Allows the user to create custom DVH Protocols, then compare up to 5 Plans/Plan Sums. The protocol automatically highlights failing normal tissues and targets. This file is designed to work for Eclipse only.
Version 8e
Submitted by: MichaelCBrewer Homepage 0 reviews

 Change machine ID for comps in XiO
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Thu Sep 30, 2010 5:10 pm
Download Now
These instructions will take you through the process of changing the machine ID for a set of beams in XiO after an optimized set of compensators have been created.
Submitted by: bkurko Homepage 0 reviews

 Change patient ID in XiO
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Thu Sep 30, 2010 5:10 pm
Download Now
Have you ever accidentally typed the wrong patient ID into XiO when creating a patient? I have. This will help you fix it.
Submitted by: bkurko Homepage 0 reviews

 Correction for PET-CT image registration in Pinnacle (7.6 & 8.0)
Rating: Not rated Popularity: 1/5: Not popular Published: Mon May 24, 2010 3:52 pm
Download Now
Instructions to correct for image registration offset when using the "copy transformation" function in Pinnacle.
Version 1.0
Submitted by: jhowe Homepage 0 reviews

 Corvus vs. Pinnacle IMRT comparison
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Fri Jun 23, 2006 8:29 pm
Download Now
Word document detailing a few brief tests and comparisons run between Pinnacle 7.4f IMRT with DMPO and Corvus 6.2.
Submitted by: nathanchildress Homepage 0 reviews

 Create 10 Subarcs from arc Version 2.1
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Updated: Mon Jun 14, 2010 11:23 am
Download Now
This script creates 10 (or 20) subarcs in Eclipse from a RapidArc plan with 1 or 2 arcs. The 10 (or 20) subarcs are in a single plan so that the plan is easily exportable to RadCalc.
Version 2.1
Submitted by: Joe64 Homepage 0 reviews

 Create 10 Subarcs from arc Version 2.1 French version
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Thu Oct 14, 2010 11:19 am
Download Now
Use this when using French XP and French Eclipse.
Version 2.1FR
Submitted by: Joe64 Homepage 0 reviews

 CSI - McGill Technique
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Fri Feb 12, 2010 12:49 pm
Download Now
CSI - Supine with three three isocenters
Submitted by: scottdube Homepage 0 reviews

 CT Scan of Varian IGRT Couch
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Tue Feb 12, 2013 6:33 pm
Download Now
This is a full CT scan of a Varian IGRT Couch.
Version 1.0
Submitted by: nathanchildress Homepage 1 review

 Delux Tangent.xls
Rating: Not rated Popularity: 2/5: Slightly below average Published: Wed May 26, 2010 3:02 pm
Download Now
This excel spreadsheet will function as a tangent calculating sim sheet while it simultaneously creates a framework for drawing a wire contour.
Version 2
Submitted by: Ebutler Homepage 0 reviews

 Dose-volume constraints for OARs
Rating: Average Popularity: 5/5: Very popular Updated: Wed Oct 24, 2012 10:06 pm
Download Now
An Excel file listing DVH limits (with RTOG and article references) for conventional, 1, 3, and 5 fraction treatments. Also includes a simple BED calculator using the linear/quadratic model.
Version 3.0
Editor's Pick Submitted by: nathanchildress Homepage 1 review

 DVH Limits (Emami et al)
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Fri May 28, 2010 12:10 am
Download Now
EXCEL spreadsheet which takes DVH dose values for organs identified in classic paper by Emami et al. and shows whether the limits are exeeded (at 100%, 2/3 and 1/3 volume points). Good for quick checks of DVH values.
Submitted by: rbenson Homepage 0 reviews

 DVH-LQtrasformation-PinnacleScript
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Tue Mar 30, 2010 12:44 pm
Download Now
This script generate a radiobiological (LQ) transformation of the physical dose distribution which incorporate fraction size effect so it is possible estimate with more precision the biological effect of the treatment.
Version 1.1
Submitted by: Berdondini Homepage 0 reviews

 ELECTRON DOSE, ROF AND MU CALCULATION FORM
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Updated: Tue Oct 24, 2006 7:50 pm
Download Now
A modifiable Excel form to calculate Dose/Fraction values, ROF values and MU/Fraction values for small and large electron fields.
Version 2
Editor's Pick Submitted by: JRG1 Homepage 0 reviews

 Enhanced Dynamic Wedge Factors (EDW)
Rating: Not rated Popularity: 3/5: Average Published: Tue Mar 11, 2008 1:40 pm
Download Now
Excel spreadsheet to calculate enhanced dynamic wedge factors for 6X and 18X.
Version 1.0
Submitted by: jhowe Homepage 0 reviews

 FracMod
Rating: Not rated Popularity: 2/5: Slightly below average Published: Sat Aug 18, 2012 1:23 pm
Download Now
FracMod is a MATLAB® executable file that calculates the variogram fractal dimension (FD) of planned intensity modulated radiation therapy (IMRT) treatment fields that are exported from EclipseTM in generic dosimetry exchange format (DXF).
Version 1.0
Submitted by: villarre Homepage 0 reviews

 Guide to Pinnacle Administration
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Updated: Wed Oct 13, 2010 3:19 pm
Download Now
This is a Word document describing common administrative tasks in Pinnacle, such as adding DICOM nodes, using Unix commands, troubleshooting problems, etc.
Version 1.1
Submitted by: nathanchildress Homepage 0 reviews

 Hand calculation workbook
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Wed May 26, 2010 4:15 pm
Download Now
Workbook for performing hand calculations.

The MLC shape import on the first 6 sheets is designed to receive from CMS XiO.
Version 5.3.0
Submitted by: bkurko Homepage 0 reviews

Page: 1, 2, 3  Next

Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.
Interactive software released under GNU GPL, Code Credits, Privacy Policy